Feasibility study on the application of DMF membrane pre-treatment system for SWRO in naval vessels |
Authors: ZOU Shiyang1, ZHANG Jianping1, WU Junrong1, DING Bingquan1, HUANG Fumin1, LIN Qingqi1, ZHU Kangsheng2, YIN Tongyao2 |
Units: 1.Naval Medical Research Institute, Shanghai 200433, China; 2.The PLA NO.4812 Factory, Anqing, 246016, China |
KeyWords: direct microfiltration technology; seawater reverse osmosis; pre-treatment; PVDF membrane |
ClassificationCode:TQ028.8 |
year,volume(issue):pagination: 2011,31(4):70-73 |
Abstract: |
Feasibility study on the application of direct microfiltration (DMF) in the pre-treatment of seawater reverse osmosis (SWRO) in naval vessels was performed by using domestic polyvinylidene fluoride (PVDF) hollow fibre membrane. High turbidity raw seawater was treated under the following conditions: DMF processing for 20 min, double-wash with water and compressed air for 30 sec, backwash of filtrated water for 30 sec, and filthy water discharge for 5 sec. Experimental results showed that silt density index (SDI) of filtrated water after DMF processing lowered to 2.9 or less, turbidity decreased to 0.9 NTU. Microfiltrtation membrane had a good anti-pollution feature. When the trans-membrane pressure (TMP) of the DMF processing system was higher than 37 kPa, back purging with sodium hypochlorite and hydrochloric acid could restore the TMP to a lower level. The DMF pre-treatment system had the features of being compact, easy for operation and stable output of quality filtrated water, which could meet the demands specified in related standards concerning development of shipboard equipment. We believe that this DMF system could be used in the pre-treatment of seawater with SWRO aboard naval vessels. |
Funds: |
AuthorIntro: |
邹士洋(1979-),男,安徽桐城人,硕士,助理研究员,主要从事水处理技术与装备研究。TEL:02181883283 13611801798 E-mail: zoushy@hotmail.com Add:上海市杨浦区翔殷路880号新科技楼 219室 Post: 200433 |
Reference: |
[1] 汪国祥,干秦湘,刘潜,等.反渗透海水淡化技术在舰船上的应用研究[J].船舶科学技术,2005,27(增刊): 7-10. [2] 干钢,陈丽雅,杜鹏飞.海岛一体化制水装置研究与应用示范[J].水处理技术,2010,36(4):118-121. [3] 叶战军.舟山市岱山县长涂海水淡化厂的设计[J].中国给水排水,2009,25(14):40-52. [4] 徐佳,阮国岭,高从堦.超滤膜预处理在胶州湾海水淡化的应用[J].水处理技术,2007,33(7):64-67. [5] 刘耀璘,胡国付,顾平.混凝/微滤用于反渗透海水淡化的预处理[J].中国给水排水,2005,21(11):50-52. [6] Vial D, Doussau G.The use of microfiltration membranes for seawater pretreatment prior to reverse osmosis membranes [J].Deslination,2002, 153: 141-147. [7] 胡国付,沙布, 刘耀璘,等.海水预处理一体化混凝-微滤工艺[J].膜科学与技术,2007,27(4):55-59. [8] 李璟,吕晓龙,马世虎.海水淡化中连续膜过滤技术的工艺优化研究[J].膜科学与技术,2006,26(3):65-69. [9] 马敬环,黄锦言,秦竞蕊.反渗透海水淡化预处理工艺研究[J].盐业与化工,2006,35(6):13-14. [10] 原培胜.船用海水淡化装置的预处理技术[J].船舶科学技术,2007,29(1):72-74. [11] 徐佳,苏保卫,高忠文,等.超滤用于海水淡化预处理的研究进展[J].膜科学与技术,2007,27(1):73-78 |