Nafion?/PANI composite membranes by in situ polymerization for direct methanol fuel cell |
Authors: YANG Jinyan1*, WEI Xiaolan2, MENG Hui3 |
Units: 1. School of Chemistry and Envirment, Jiaying University, Meizhou Guangdong |
KeyWords: PANI; Nafion?112 membrane; proton conductivity; methanol permeability; DMFC |
ClassificationCode:TM911.4; O646 |
year,volume(issue):pagination: 2011,31(4):22-26 |
Abstract: |
Aniline monomer had been polymerized in Nafion®112 membrane using (0.1 mol?L-1)(NH4)2S2O8 /(1 mol?L-1) HCl solution as oxidant by an in situ chemical polymerization method. Scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX) measurements indicated that there was an obvious difference between the plane of the composite membrane and Nafion®112 membrane, polyaniline (PANI) was mainly located in the two sides of the membrane. FT-IR spectroscopy of the composite membrane showed that the characteristic bands of PANI can be observed in it which meant PANI was successfully polymerized in Nafion®112 membrane. The proton conductivity of composite membrane was slightly lower than that of Nafion®112 membrane under completely humidity conditions, but the methanol crossover of composite membranes were obviously reduced. The permeability of NF/PANI-2 membrane was 1.83×10-6 cm2?s-1 which was 44% lower than that of Nafion®112 membrane. Correspondingly the direct methanol fuel cell (DMFC) with NF/PANI-2 membrane has a 7% higher open circuit voltage (OCV) and 30% higher maximum power density than that of Nafion®112 membrane. |
Funds: |
AuthorIntro: |
杨金燕(1970-),女,陕西人,博士,讲师,主要从事质子交换膜的研究. * 通讯联系人,E-mail: yangjinyanr@126.com |
Reference: |
[1] Silav V S, Schirmer J, Reissner R, et al. Proton electrolyte membrane properties and direct methanol fuel cell performance II.Fuel cell performance and membrane properties effects[J]. J Power Sources, 2005, 140: 41-49. [2] 任素贞,梁振兴,辛勤,等. 直接甲醇燃料电池用质子交换膜研究进展[J]. 膜科学与技术, 2005, 25(4): 51-55. [3] San P J, Zeng C L, Zhi Q T. Layer-by-Layer Self-Assembly of Composite Polyelectrolyte-Nafion Membranes for Direct Methanol Fuell Cells[J]. Adv Mater, 2006, 18: 1068-1072. [4] Bae B C, Ha H Y, Kim D J. Nafion®-graft-polystyrene sulfonic acid membranes for direct methanol fuel cells [J]. J Membr Sci, 2006, 276: 51-58. [5] Chen Z W, Holmberg B, Li W Z, et al. Nafion/Zeolite Nanocomposite Membrane by in Situ Crystallization for a Direct Methanol Fuel Cell [J]. Chem Mater, 2006,18: 5669-5675. [6] Marie E, Rothe R, Antonietti M, et al. Synthesis of Polyaniline Particles via Inverse and Direct Miniemulsion[J]. Macromolecules, 2003, 36: 3967-397. [7] Dan A, Sengupta P K. Synthesis and Characterization of Polyaniline Prepared in Formic Acid Medium[J]. J Appl Polym Sci, 2004, 91: 991-999. [8] Karami H, Mousavi M F, Shmsipur M. A novel dry bipolar rechargeble battery based on polyaniline[J]. J Power Sources, 2003, 124: 303-308. [9] Gharibi H, Zhiani M, Mirzaie R A, et al. Investigation of polyaniline impregnation on the performance of gas diffusion electrode (GDE) in PEMFC using binary of Nafion and polyaniline nanofiber[J]. J Power Sources, 2006, 157: 703-708. [10] Tan S, Be´langer D. Characterization and Transport Properties of Nafion/Polyaniline Composite Membranes[J]. J Phys Chem B, 2005, 109: 23480-23490. [11] Roeder J, Zucolotto V, Shishatskiy S, et al. Mixed conductive membrane: Aniline polymerization in an acid SPEEK matrix[J]. J Membr Sci, 2006, 279: 70-75. [12] Nagarale R K, Gohil G S, Shahi V K. Sulfonated poly(ether ether ketone)/polyaniline compositeproton-exchange membrane[J]. J Membr Sci, 2006, 280: 389-396. [13] Lee C H, Park H B, Lee Y M, et al. Importance of Proton Conductivity Measurement in Polymer Electrolyte Membrane for Fuel Cell Application[J]. Ind Eng Chem Res, 2005, 44: 7617-7626. [14] Ramya K, Dhathathreyan K S. Direct methanol fuel cells: determination of fuel crosses over in a polymer electrolyte membrane[J]. J Electroanal Chem, 2003, 542: 109-115. [15] Liang Z X, Chen W M, Liu J G, et al. FT-IR study of the microstructure of Nafion® membrane[J]. J Membr Sci, 2004, 233: 39-44. |
Service: |
【Download】【Collect】 |
《膜科学与技术》编辑部 Address: Bluestar building, 19 east beisanhuan road, chaoyang district, Beijing; 100029 Postal code; Telephone:010-80492417/010-80485372; Fax:010-80485372 ; Email:mkxyjs@163.com
京公网安备11011302000819号