Position:Home >> Abstract

Study on UF Combined Process used in Micropollution Resource Water
Authors: TANG Kai-feng  GUO Shu-qin
Units: Tian Jin Municipal Engineering Design and Research Institute, Tian Jin 300051
KeyWords: pre-oxidation;adsorption;coagulation;air flotation;ultrafiltration
ClassificationCode:TU991.2
year,volume(issue):pagination: 2011,31(5):69-72

Abstract:
In this study, potassium permanganate pre-oxidation / powdered activated carbon adsorption / flotation / ultrafiltration combined process was used for treating micro-polluted source water. The experimental results show that treated by potassium permanganate pre-oxidation / powdered activated carbon adsorption / flotation the removal rate on the turbidity, algae, CODMn and UV254 were 91.7%, 90.6%, 45.9% and 19.2% respectively. The removal rate of ultrafiltration unit on the turbidity, algae, CODMn and UV254 were 98.8%, 84.9%, 22.4%, 3.1% respectively. The NH3-N removal efficiency is not obvious. The water quality treated by the combined process can reach "sanitary standard for drinking water" (GB5749-2006) stably, and such a combined process can be recommended as the process for upgrading the existing water plant.

Funds:

AuthorIntro:
唐凯峰(1980- ),男,河北安国人。2005年毕业于哈尔滨工业大学环境工程专业,硕士研究生,现工作于天津市市政工程设计研究院,工程师,主要从事高浓度有机废水处理、污水生态处理、污水再生利用及环境影响评价等领域的设计及研究工作,已发表论文5篇,获省部级优秀咨询成果一等奖1项。电话:(022)27815311-2465手机:13920314061E-mail:laoyuantmedi@163.com1

Reference:

1. 李圭白,杨艳玲. 超滤—第三代饮用水净化工艺的核心技术. 供水技术,2007,4(1):1-3
2 胡澄澄,高乃云,楚文海. 沉淀与气浮工艺单元处理太湖原水效果比较. 给水排水,2010,36(2):13-17
3  蒋绍阶,刘宗源.  UV254作为水处理中有机物控制指标的意义. 重庆建筑大学学报,2002,24(2):61-65

Service:
Download】【Collect

《膜科学与技术》编辑部 Address: Bluestar building, 19 east beisanhuan road, chaoyang district, Beijing; 100029 Postal code; Telephone:010-80492417/010-80485372; Fax:010-80485372 ; Email:mkxyjs@163.com