Position:Home >> Abstract

Pilot Studies on Coagulation-Microfilter Process to Improve the Biostability of Drinking Water
Authors: Tao Runxian1  Chen Li1  Wang Haiyan2  GuoXingfang1  Zhu Kaidong1
Units: 1. North China Municipal Engineering Design & Research Institute, Tianjin, 300074; 2. Qingdao University of Science & Technology, Qingdao, Shandong, 266033
KeyWords: Coagulation; Microfilter; Biostability; BDOC; TP
ClassificationCode:TU991
year,volume(issue):pagination: 2012,32(1):107-111

Abstract:
A pilot study was done to evaluate the impact of the coagulation-microfilter process on reduction of nutrient levels and on the biostability of treated water. The DOC removal efficiency increased with the increase of coagulant dosing, while the average DOC removal reached to 22.4% with adding 2mg/L FeCl3 as coagulant. In addition, Biodegradable Dissolved Organic Carbon (BDOC) and Total Phosphate (TP) could be removed effectively and the BDOC and TP in effluent were below the threshold of bio-stability, which is 0.20-0.25mg/L and 5μg/L respectively. And the Bacterial Regrowth Potential (BRP) of the effluent could be degraded by 1 LOG. The results show that the coagulation- microfilter process is effective to improve the bio-stability of drinking water and to control the bacterial regrowth potential.

Funds:

AuthorIntro:
陶润先(1979-),男,工程师,主要研究方向为饮用水安全保障技术;Emial: rxtao@vip.sina.com

Reference:
[1] 李爽, 张晓健, 范晓军等.  以AOC评价管网水中异养菌的生长潜力[J].  中国给水排水, 2003, 19(1): 46-49.
[2] 李欣, 袁一星, 马建薇等.  BDOC值对管网水生物稳定性的影响[J].  中国给水排水, 2004, 20(8): 10-12.
[3] Lehtola, M. J., Miettinen, I. T., Vartiainen, T., etal.  A new sensitive bioassay for determination of microbially available phosphorus in water[J].  Applied Environmental Microbiology, 1999, 65(5): 2032-2034.
[4] Sathasivan, A., and Ohgaki, S.  Application of new bacterial regrowth potential method for water distribution system – A clear evidence of phosphorus limitation[J].  Water Research, 1999, 33(1): 137-144.
[5] 姜登岭.  营养基质对管网水悬浮菌再生长的影响研究[D].  清华大学硕士学位论文, 2004.
[6] 纪荣平, 吕锡武.  膜处理工艺对饮用水生物稳定性的影响[J].  扬州大学学报(自然科学版).  2005, 8(1): 64-67.
[7] 刘文君, 吴红伟, 王占生.  饮用水中BDOC测定动力学研究[J].  环境科学, 1999, 20(4): 20-23.
[8] 国家环保总局水和废水监测分析方法编委会编.  水和废水监测分析方法(第四版)[M]. 北京: 中国环境科学出版社, 2002.
[9] 董秉直, 曹达文, 陈艳 编.  饮用水膜深度处理技术[M].  北京: 化学工业出版社, 2006.
[10] Niquette, P., Servais, P., and Savoir, R.  Bacterial dynamics in the drinking water distribution system of Brussels[J].  Water Research, 2001, 35(3): 675-682.
[11] 赵洪宾, 李欣, 赵明 编.  给水管道卫生学[M].  北京: 中国建筑工业出版社, 2008.
[12] 桑军强, 张锡辉, 周浩辉, 王占生.  总磷作为饮用水生物稳定性控制指标的研究[J].  水科学进展, 2003, 14(6): 720-724.
[13] 方华.  饮用水生物稳定性和净水工艺对有机物去除的研究[D].  东南大学博士学位论文, 2006.