Position:Home >> Abstract

Membrane cleaning and fouling control in a pilot plant of ultrafiltration for drinking water treatment
Authors: ZHU Dan1, GU Ping1, WANG Haiyan1, HE Fenghua2, HAN Tao2
Units: School of Environmental Science and Engineering, Tianjin University, Tianjin 300072, China;2Tianjin TEDA Waterworks Company, Tianjin 300457, China
KeyWords: drinking water;membrane fouling;backwashing;chemical enhanced backwash (CEB); chemical cleaning;pre-chlorination
ClassificationCode:TU 991.2
year,volume(issue):pagination: 2012,32(4):81-86

Abstract:
A pilot-scale low pressure ultrafiltration membrane system was used to treat the finished water from a sedimention tank in the waterworks, and membrane fouling control was investigated. Physical backwashing, chemical enhanced backwash (CEB), chemical cleaning and pre-chlorination were studied for membrane fouling control. Results showed that physical backwashing have a little effect on fouling control, however, CEB, an online cleaning mode could have a great effect on fouling control, and the average recovery rate of specific flux was 85%. The effect of chemical cleaning with oxalic acid was better, after cleaning, the average SF value was increased to 265 L/(h•m2•bar). Pre-chlorination could slow down the fouling rate. In addition, the composition of the eluent was analysed. The results revealed that iron and dissolved organic matter were the major factors for fouling.

Funds:

AuthorIntro:
朱丹(1987-),女,陕西宝鸡,硕士研究生,从事饮用水膜法处理研究。 *通讯联系人,022-27405059,

Reference:
[1] 刑卫红, 童金忠, 王焕章, 等. 微滤和超滤过程中浓差极化和膜污染控制方法研究[J]. 化工进展, 2000(1): 44-48.
[2] Musale D A, Kulkami S S. Fouling reduction in poly(aerylonitrile-co-acrylamide) ultrafiltration membranes[J]. Journal of Membrane Science, 1996, 111(1): 49-56.
[3] 张博丰, 马世虎. 超/微滤膜的膜污染与膜清洗研究[J]. 供水技术, 2009, 3(6): 13-16.
[4] 沈悦啸, 王利政, 莫颖慧, 等. 膜污染和膜材料的最新研究进展[J]. 中国给水排水, 2010, 26(14): 16-22.
[5] Yoon S H, Kim H S, Yeom I T. Optimization model of submerged hollow fiber membrane modules[J]. Journal of Membrane Science, 2004, 234(1-2): 147-156.
[6] Chang S, Fane A G. Filtration of biomass with laboratory scale submerged hollow fibre modules: effect of operating conditions and module configuration[J]. Journal of Chemical Technology and Biotechnology, 2002, 77(9): 1030-1038.
[7] 董秉直, 刘凤仙, 桂 波. 在线混凝处理微污染水源水的中试研究[J]. 工业水处理, 2008, (1): 40-43.
[8] 罗 虹, 顾 平, 杨造燕. 投加粉末活性炭对膜阻力的影响研究[J]. 中国给水排水, 2001, 17(2): 1-4.
[9] Heng Liang, Yanglin Yang, Weijia Gong, et al. Effect of pretreatment by permanganate/chlorine on algae fouling control for ultrafiltration(UF) membrane system[J]. Desalination, 2008, 222(1-3): 74-80.
[10] Shimizu Y, Okuno Y, Uryu K, et al. Filtration characteristics of hollow fiber microfiltration membranes used in membrane bioreactor for domestic wastewater treatment[J]. Water Research, 1996, 30(10): 2285-2392.
[11] 王 湛. 膜分离技术基础[M]. 北京:化学工业出版社, 2000.
[12] Faust S D, Aly O. Chemistry of Water Treatment[M]. USA: CRC, 1998.
[13] Lee H, Amy G, Cho J, et al. Cleaning strategies for flux recovery of an ultrafiltration membrane fouled by natural organic matter[J]. Water Research, 2001, 35(14): 3301-3308.
[14] Al-Amoudi A, Lovitt R W. Fouling strategies and the cleaning system of NF membranes and factors affecting cleaning efficiency[J]. Journal of Membrane Science, 2007, 303(1-2): 4-28.
[15] Thurman E M. Organic Geochemistry of Natural Waters[M]. USA: Kluwer Academic Publishers, 1985.
[16] Arnal J M, Garcia-Fayos B, Sancho M, et al. Cleaning ultrafiltration membranes by different chemical solutions with air bubbles[J]. Desalination and Water Treatment, 2009, 10(1-3): 175-180.
[17] 董秉直, 曹达文, 陈 艳. 饮用水膜深度处理技术[M]. 北京:化学工业出版社, 2006.
[18] Strugholtz S, Sundaramoorthy K, Panglisch S, et al. Evaluation of the performance of different chemicals for cleaning capillary membranes[J]. Desalination, 2005, 179(1-3): 191-202.
[19] Yinghui Mo, Jianhua Chen, Wenchao Xue, et al. Chemical cleaning of nanofiltration membrane filtrating the effluent from a membrane bioreactor[J]. Separation and Purification Technology, 2010, 75(3): 407-411.
[20] 张玲玲. 混凝-微滤工艺制备饮用水的试验研究[D]: [学位论文].天津: 天津大学环境科学与工程学院, 2008.
[21] Choo K H, Lee H, Choi S J. Iron and manganese removal and membrane fouling during UF in conjunction with prechlorination for drinking water treatment[J]. Journal of Membrane Science, 2005, 267(1-2): 18-26.
[22] Chang Y J, Choo K H, Benjamin M M, et al. Combined adsorption/UF process increases TOC removal[J]. Journal of the American Water Works Association, 1998, 90(5): 90-102.
 

Service:
Download】【Collect

《膜科学与技术》编辑部 Address: Bluestar building, 19 east beisanhuan road, chaoyang district, Beijing; 100029 Postal code; Telephone:010-80492417/010-80485372; Fax:010-80485372 ; Email:mkxyjs@163.com