Abstract: |
With the hollow fiber membrane modules from Tianjin MTIMO Membrane Technology Co., Ltd to construct MBR system, the own-designed and manufactured pilot test on biological Nitrogen and Phosphorus Removal by using Reverse A2O-MBR process to treat wastewater was studied. The research results show that the average effluent concentrations of COD,NH3-N,TN and TP are 22.23mg/L,1.89mg/L,14.96mg/L,and 0.38mg/L respectively. The average removal rate of COD,NH3-N,TN and TP are 91.49%,94.5%,63.4%,and 87.3% respectively. The NTU of effluent was less than 0.19. Steadily operating data shows that the average effluent concentrations are achieving I-A criteria specified in the Discharge standard of pollutants for municipal wastewater treatment plant (GB18918-2002), and normally the average effluent concentrations are achieving the I-B criteria. The contaminate membrane modules were cleaned by the composite alkali substances or the composite alkali-acid substances.TMP(Trans-membrane pressure)are from 43kpa,73kpa falling to 12kpa,25kpa respectively. The recoveries are 31kpa, 48kpa respectively. The mass fluxes of membrane modules are recovered. |
Funds: |
国家水体污染控制与治理科技重大专项资助(2011ZX07317-001) |
AuthorIntro: |
刘圣根(1983 —),男,江西宜春人,硕士,研究方向为膜法污水处理研究. *通讯联系人 |
Reference: |
[1] Chaize S,Huyard A. Membrane bioreactor on domestic wastewater treatment sludge production and modeling approach [J].Water Sci Technol,1991,23(7-9):1591-1600 [2] Tom S,Judd S,Bruce J,etal. Membrane bioreactor for wastewater treatment [M].London:LWA publishing,2000 [3] 王建华,徐又一,朱宝库.膜生物反应器的研究及其在废水处理中的应用[J].膜科学与膜技术,2003,23(4):224-233 [4] 操建华,朱宝库,徐又一.外置式中空纤维膜-生物反应器处理污水的研究[J].膜科学与膜技术,2006,26(4):48-51, 56 [5] 曹斌,黄霞,北中敦,等.A2O-膜生物反应器强化生物脱氮除磷中试研究[J].中国给水排水,2007,23(3):22-26 [6] 朱宁伟,李激,郑晓英,等.A2O-MBR组合工艺处理城市污水的试验[J].中国给水排水,2010,26(15):1-4 [7] 朱亮,朱凤春,许旭昌,等.MBR/PAC组合工艺处理污水厂尾水的中试研究[J].中国给水排水,2009,25(5):59-62 [8] 陆日明,苏伟健.珠三角地区A2O工艺和倒置A2O工艺运行效果研究[J].水处理技术,2012(7) [9] 崔新伟,谢丽,毕晔,等.倒置A2O-MBR工艺处理低C/N生活污水脱氮性能研究[J],给水排水,2012,38(9):132-136 [10] 国家环境保护局.水和废水监测分析方法[M],第四版.北京:中国环境科学出版社,2002,49~706 [11] 郑燕青,周建华.除磷工艺中厌氧释磷和好氧吸磷的影响因素[J].中国市政工程,2007(1):48-50 |
Service: |
【Download】【Collect】 |
《膜科学与技术》编辑部 Address: Bluestar building, 19 east beisanhuan road, chaoyang district, Beijing; 100029 Postal code; Telephone:010-80492417/010-80485372; Fax:010-80485372 ; Email:mkxyjs@163.com
京公网安备11011302000819号