Discussion about the assessment of ultrafitration membranes retention performance by seprating protein method |
Authors: Luo Ming, Shang Min, Zhengxiang* |
Units: School of environment and natural resources, Renmin University of China, Beijing, 100872 |
KeyWords: ultrafitration membrane; MWCO; standard substance. |
ClassificationCode:TQ028 |
year,volume(issue):pagination: 2014,34(6):56-61 |
Abstract: |
Solute rentention method is widely used for determining the ultrafitration membrane separation performance. This study investigates the accuracy of MWCO (Molecular Weight Cut Off) determined by using different protein molecules. A series of experiments have been carried out to determine protein retention in various conditions (runtime, protein concentration and transmembrane pressure) during filtration through hollow fiber membrane and flat-sheet membrane. The results show the BSA rejection rate increased as the initial concentration increasing, the retention rate changed from 3.5% to 80.7% when initial concentration increased 100mg/L to 1000mg/L. And the MWCO was inaccurate with high concentration of protein molecules. High concentration may cause error of the MWCO test, but low concentration may influence the stability of the test results. With adjusting the concentration to 100-500mg/L and the runtime to 40min, the data of MWCO could be more reliable. |
Funds: |
“十二五”国家科技支撑计划:村镇建设工程标准体系研究(2012BAJ19B02);教育部“新世纪优秀人才支持计划资助”(NCET-12-0531) |
AuthorIntro: |
罗鸣(1989- ),女,籍贯陕西,中国人民大学硕士研究生,主要从事水处理与膜技术研究, |
Reference: |
[1] 吕晓龙. 中空纤维多孔膜性能评价方法探讨[J]. 膜科学与技术, 2011(2): 1-6. [2] Arkhangelsky E, Duek A, Gitis V. Maximal pore size in UF membranes[J]. Journal of Membrane Science, 2012, 394–395: 89-97. [3] Zhao C, Zhou X, Yue Y. Determination of pore size and pore size distribution on the surface of hollow-fiber filtration membranes: a review of methods[J]. Desalination, 2000, 129(2): 107-123. [4] GB/T 20103-2006. 膜分离技术 术语[S]. [5] HY/T 050-1999. 中空纤维超滤膜测试方法[S]. [6] ASTM E1343-1990(2001). 平板超滤膜的分子量界限评定的测试方法[S]. [7] JIS K3821-1990. 超滤组件的纯净水渗透性能测试方法[S]. [8] HJ/T 271-2006. 环境保护产品技术要求.超滤装置[S]. [9] HY/T 062-2002. 中空纤维超滤膜组件[S]. [10] HY/T 112-2008. 超滤膜及其组件[S]. [11] 吴金克,王彬. 超滤膜截留性能测定方法的研究[J]. 化学工程师, 2000(01): 3-5. [12] 潘献辉,王晓楠,张艳萍,等. 超滤膜截留性能检测用基准物质研究与应用进展[Z]. 青岛: 2012. [13] 张晓慧,罗嫣,隋军,等. 超滤膜性能指标检测技术现状[J]. 价值工程, 2010(22): 111-112. [14] 董声华,郑领英. 不同标准物表征超滤膜截留性能的比较[J]. 水处理技术, 1993(06): 17-21. [15] 周晨,陆晓峰,侯铮迟,等. 分光光度法和总有机碳法对超滤膜截留性能测定的比较[J]. 膜科学与技术, 2011(05): 34-39. [16] 吕晓龙. 超滤膜孔径及其分布的测定方法──Ⅰ.常用测定方法讨论[J]. 水处理技术, 1995(3): 137-141. |
Service: |
【Download】【Collect】 |
《膜科学与技术》编辑部 Address: Bluestar building, 19 east beisanhuan road, chaoyang district, Beijing; 100029 Postal code; Telephone:010-80492417/010-80485372; Fax:010-80485372 ; Email:mkxyjs@163.com
京公网安备11011302000819号