Remission factors of membrane fouling for treatment of papermaking wastewater by MBR |
Authors: TANGWuxiao,LI Weixing*, XING Weihong |
Units: State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemistry and Chemical Engineering, Nanjing Tech University, Nanjing 210009, China |
KeyWords: MBR; papermaking wastewater; aeration; GAC; membrane fouling |
ClassificationCode:TQ028.8 |
year,volume(issue):pagination: 2016,36(2):102-107 |
Abstract: |
With the increase of the amount of papermaking wastewater, improvement of the traditional process was imminent extremely. As a new efficient treatment process, membrane bioreactor (MBR) was able to cope with this problem commendably.However, the key to the MBR widespread application in papermaking wastewater was to reduce the membrane fouling problem. This paper aimed to study membrane fouling mitigation methods.The results showed that the effect of air and mechanical scouring could effectively alleviate membrane fouling. The purpose of reducing membrane fouling could be fully realized with the membrane surface washed when the aeration intensity reached to 1800 L/(m2·h). Adding to support medium into the bioreactorcould ensure the change of transmembrane pressure (TMP) at a low aeration. Furthermore, it reduced membrane fouling and energy consumption. |
Funds: |
国家科技支撑项目课题(No.2013BAE11B01);江苏省六大人才高峰项目(2013-XCL-027) |
AuthorIntro: |
作者简介:唐吴晓(1989-),男,四川自贡人,硕士,南京工业大学硕士生。主要研究方向为膜应用。通讯联系人,E-mail:wxli@njtech.edu.cn. |
Reference: |
[1] Simstich B, Beimfohr C, HornH. Lab scale experiments using a submerged MBR under thermophilic aerobic conditions for the treatment of paper mill deinking wastewater[J]. Bioresource Technol, 2012, 122:11-16. [2] QuX, GaoWJ, HanMN, et al. Integrated thermophilic submerged aerobic membrane bioreactor and electrochemical oxidation for pulp and paper effluent treatment – towards system closure[J]. Bioresource Technol, 2012, 116: 1-8. [3] BrownK, GhoshdastidarAJ, HanmoreJ, et al. Membrane bioreactor technology: a novel approach to the treatment of compost leachate[J]. Waste Manage, 2013, 33(11): 2188-2194. [4] WangX H, QianJ J, LiX F, et al. Influences of sludge retention time on the performance of submerged membrane bioreactors with the addition of iron ion[J]. Desalination, 2012, 296: 24-29. [5] SantosA, MaW, JuddSJ. Membrane bioreactors: Two decades of research and implementation[J]. Desalination, 2011, 273(1): 148-154. [6] Judd S. The status of membrane bioreactor technology[J]. TrendsBiotechnol, 2008, 26(2): 109-16. [7] Le-ClechP. Membrane bioreactors and their uses in wastewater treatments[J]. Appl Microbiol Biotechnol, 2010, 88(6): 1253-1260. [8] ZhangY Z, Ma C M, YeF, et al. The treatment of wastewater of paper mill with integrated membrane process[J]. Desalination, 2009, 236(1-3): 349-356. [9] Martín-PascualJ, Reboleiro-RivasP, López-LópezC, et al. Influence of hydraulic retention time on heterotrophic biomass in a wastewater moving bed membrane bioreactor treatment plant[J]. Int J Environ Sci Technol, 2014, 11(5): 1449-1458. [10] 应京强,高彦昌,杨永哲. 基于跨膜压差变化特征的膜生物反应器曝气条件的优化[J]. 膜科学与技术, 2014, 34(2): 45-50. [11] PradhanM, VigneswaranS, KandasamyJ, et al. Combined effect of air and mechanical scouring of membranes for fouling reduction in submerged membrane reactor[J]. Desalination, 2012, 288: 58-65. |