Position:Home >> Abstract

Study on the Fouling Propensity of Effluent from the MBR System for the Electronics Wastewater with High Salinity
Authors: Han Yongping1, Zhang Yuan1, Li Keyi1, Liu Xiaoyan1、XiaoYan2, Wang Xiaolin2
Units: 1. Beijing Key Laboratory of the Resource Utilization of Biomass Waste, Biochemical Engineering College, Beijing Union University, Beijing 100023 2. Beijing Key Laboratory of Membrane Materials and Engineering, Department of Chemical Engineering, Tsinghua University, Beijing 100084
KeyWords: Electronics Wastewater, MBR, RO, Membrane Fouling
ClassificationCode:TQ028.8
year,volume(issue):pagination: 2016,36(5):81-86

Abstract:
 To the electronics wastewater with high salinity, the fouling propensity of effluent from the MBR system plays an important role for the design and long-term operational sustainability of the MBR+RO system. In this text, the effluent quality, settling performance and RO membrane fouling were researched with EEM and SEM-EDS. The results showed that there were a few organic matters with a strong adhesion in the effluent. The metal ions in the effluent not only had a complexation reaction with the macromolecules humus acid and protein, but also with silicon colloid. It caused a compacts structure fouling layer on the RO membrane surface. But the organic matters and most of metal ions could form settling of flocs to be removed from the effluent by improving pH of the effluent to 10, which would relieve the membrane fouling. In addition, the removal of metal ions in the fouling layer was critical for enhancing the cleaning efficiency of RO membrane.

Funds:

AuthorIntro:
第一作者简介:韩永萍(1971.6),女,山东曹县,博士,副教授,主要从事膜科学技术的应用与教学研究,E-mail:hypyyt@163.com

Reference:
 1.许燕滨,段晓军,罗庆旺等.一体化膜生物反应器处理印刷线路板综合废水[J].电镀与涂饰,2010,29(6):38~41
2.谷维梁,刘立华.电子废水MBR+RO法处理回用中试研究[J].产业玉科技论坛,2012,11 (22):96 ~97
3.张静.北小河污水处理厂反渗透系统的调试运行和保存[J].中国给水排水,2010,26 (2):93 ~98
4.肖燕,韩永萍,王晓琳.面向半导体废水回用处理的MBR-RO组合工艺可行性[J].水处理技术,2013,39(2):102~106
5. Okamki M, Uraki M, Miur K, et al. Water recycling using sequential membrane treatment in the electronics industry [J]. Desalination, 2000, 131: 65~73
7.刘铮,董秉直,陈艳等.三维荧光光谱表征膜污染物[J].环境化学,2010,29 (3):496 ~501
8.曾晓岚,韩乐,丁文川等. RO处理早期垃圾渗滤液中 DOM的荧光光谱分析[J].光谱学与光谱分析,2011,31 (10):2767~2770
 