Abstract:
 On the basis of particular reference parameters and the flow velocity of 2m/s, the operational 
conditions of reverse osmosis (RO) system under different runoff directions were analyzed by using the simulation software which can reflect the pipeline pressure drop. Two operating parameters of water yield and cross flow 
ratio in a whole membrane shell were proposed to characterize the fouling rate and defouling intensity for each 
membrane shell, respectively. It is found that non-uniform fouling distribution in each membrane shell was 
mainly attributed to unbalance water yield. Moreover, the results showed that the membranes at the bottom 
membrane shells suffered from relative severe fouling during the current applications of RO systems with the flow rate of 2 m/s. 
 

Funds:

AuthorIntro:
作者简介:汪艳宁(1975-),女,西安人,硕士,讲师,从事膜工艺技术研究,E-mail:wangyanning@tcu.edu.cn

Reference:
[1] 罗  浩. 反渗透膜元件及膜系统的数学模型[J]. 工业水处理,2009,29(12):79-82.
[2] 靖大为,苏卫国. 离散元件与管道参数的反渗透系统数学模型[J]. 膜科学与技术,2011,31(2):35-38.
[3] 靖大为. 反渗透系统优化设计与运行[M]. 北京:化学工业出版社, 2016.2
[4] 伍悦滨,王芳. 工程流体力学[M]. 北京:中国建筑工业出版社, 2006.2
[5] 王文娜. 有机污染膜系统中的污染物质量分布[J]. 工业水处理.2015,35(5):34-38.
 

Service:
Download】【Collect

《膜科学与技术》编辑部 Address: Bluestar building, 19 east beisanhuan road, chaoyang district, Beijing; 100029 Postal code; Telephone:010-80492417/010-80485372; Fax:010-80485372 ; Email:mkxyjs@163.com

京公网安备11011302000819号