Studies on evaluation method for desulfurization efficiency of hollow fiber membrane contactor |
Authors: GUAN Yipeng1,XING Yangyang1,2,LIU Zheng1,ZHANG Hong2,CHEN Ying1 |
Units: 1.The Institute of Seawater Desalination and Multipurpose Utilization, SOA(Tianjin),Tianjin 300192,China; 2. School of Materials Science and Engineering, Dalian Polytechnic University, Dalian 116034,China |
KeyWords: hollow fiber membrane; membrane contactor; mass transfer performance; evaluation method |
ClassificationCode:TQ028.8;X701.3 |
year,volume(issue):pagination: 2016,36(6):42-46 |
Abstract: |
A study of flue gas desulfurization was carried out using self-developed box-type hydrophobic polypropylene hollow fiber membrane contactor with which desalted water, sodium hydroxide and ammonium sulfite were chosen as absorbents. The effects of various influent factors on membrane utility were investigated, such as the absorbent selection, the concentration of the absorbent, the gas-liquid ratio, the concentration of SO2, the temperature of gas and liquid. Accordingly, the mass transfer performance index system and the evaluation method of membrane contactor were proposed and established. The research results showed that the absorbent concentration, gas-liquid ratio and concentration of SO2 were key factors to the desulfurization efficiency, while the influence of temperature of gas and fluid was not obvious. It is indicated that the membrane utility and desulfurization performance index could be accurate on the condition that a specified concentration of ammonium sulfite solution was chosen as absorbent with the corresponding conditions of temperature, pressure and flue gas concentration. |
Funds: |
基金项目:2013海洋公益性行业科研专项经费项目(201305004) |
AuthorIntro: |
第一作者简介:关毅鹏(1980-),男,吉林敦化人,学士,高级工程师,从事膜技术研发与应用. E-mail:114324092@qq.com,*通讯作者,E-mail:chy786@qq.com |
Reference: |
[1] Rob Klaassen. Achieving flue gas desulphurization with membrane gas absorption [J].Filtration & Separation, 2003,40(10):26-28. [2] S.N.Ashrafizadeh, Z.Khorasani. Ammonia removal from aqueous solutions using hollow-fiber membrane contactors [J]. Chemical Engineering Journal,2010,162 (1):242-249. [3] V.Y. Dindorea, D.W.F. Brilmanc, G.F. Versteegb. Modelling of cross-flow membrane contactors: physical mass transfer processes [J].Journal of Membrane Science,2005,251(1-2):209– 222. [4] 陈颖,关毅鹏,郭春刚,等.气-液膜接触器结构优化及其传质性能研究[J].膜科学与技术,2012,32(3):52-58. [5] 崔振东,侯纯扬,陈颖,等.膜吸收法浓海水烟气脱硫试验研究[J].膜科学与技术, 2010,31(1):84-88. [6] 邵申,孙在柏,万皓,等.氨法烟气脱硫技术的工艺研究[J].环境工程,2011,29(5): 71-74. [7] 环境保护部国家质量监督检验检疫总局.GB 13223-2011,火电厂大气污染物排放标准[S].北京:中国环境科学出版社, 2011. [8] 朱宝库,陈炜,王建黎,等.膜接触器分离混合气中二氧化碳的研究[J].环境科学, 2003,24(5):34-38. [9] 瞿如敏,沙焱,陈浩,等.聚丙烯中空纤维膜组件分离烟气中的CO2[J].化工进展,2013, 32(11):2778-2782. |