Position:Home >> Abstract

Study on MABR application in city river bioremediation
Authors: Hao Li1, Peng Li2, Linquan Sun2,Chunbing Yang3, Bo Li1,Baoan Li2, 
Units: 1Tianjin Binhai Hi-tech Industry Development Zone Management Committee, Tianjin 300384, PR China 2Chemical Engineering Research Center, State Key Laboratory of Chemical Engineering, Tianjin Key Laboratory of Membrane Science and Desalination Technology, Collaborative Innovation Center of Chemical Science and Engineering (Tianjin)., Tianjin 300072, PR China 3Tianjin Hydroking Sci & Tech Ltd., Tianjin 300072, PR China
KeyWords: MABR; City river water body; Bioremediation; Cyanobacteria; Nitrogen and phosphorus removals
ClassificationCode:X522
year,volume(issue):pagination: 2016,36(6):101-107

Abstract:
 In this study, the water quality of Haitai North-South Street Landscape River was evaluated to be eutrophication and the water quality was worse than the surface water environmental quality standard (GB3838-2002) V. The increase of nitrogen and phosphorus content was the main factor that causing the river water blooms. Aiming at the existing problem, membrane aerated biofilm reactor (MABR) bioremediation solution was put forward. Aquatic plants type MABR membrane component and water body bioremediation system were designed. Afterwards, the MABR system was continuously operated and monitored for 5 months. The results indicated that the MABR bioremediation system significantly improved the self-purification capacity of Haitai North-South Street Landscape River. In the treated river water, the NH3-N, COD and TP concentrations met the surface water environmental quality standard (GB3838-2002) III or IV and the TN concentration met the surface water environmental quality standard (GB3838-2002) V. The algal bloom was not observed in the entire operating period. Thus, MABR technology has wide application prospect in river water bioremediation.

Funds:
本项目获得了天津市科技支撑计划项目(14ZCDGSF00031和13ZCZDSF00500)和国家自然科学基金(51478304)资助。

AuthorIntro:
李浩(1978-),男,天津市,博士学位研究生,研究方向:管理科学与工程。联系电话:15510970177,Email:1158915455@qq.com

Reference:
 [1] 朱颜明, 黎劲松, 杨爱玲.城市饮用水地表水源非点源污染研究[J].城市环境与城市生态, 2000,13(4):1-4. [Zhu yanming, Li jinsong, Yang ailing. Urban drinking surface water sources of non-point source pollution[J]. Urban Environment & Urban Ecology, 2000, 13(4), 1-4.]
[2] Yang Y, Wei Y S, Zheng X, et al. Investigation of microbial contamination in Wenyu River of Beijing[J]. Acta. Scien. Circum, 2012, 3, 29-18.
[3] Wei X, Li B A, Zhao S, et al. Pharmaceutical wastewater treatment by integrated membrane-aerated biofilm reactor (MABR) system- A pilot-scale study[J]. Bioresour. Technol, 2012, 122, 189-195.
[4] Terada A, Yamamoto Y, Igarashi R, etal. Feasibility of a membrane aerated biofilm reactor to achieve controllable nitrification[J]. Biotechnology and bioengineering, 2006, 28(2), 123-130.
[5] Patel J, Nakhla G. Interaction of denitrification and P removal in anoxic P removal systems[J]. Desalination, 2006, 201: 82-99.
[6] Carles P N, Barth F S. Structure, composition, and strength of nitrifying membrane-aerated biofilms[J]. Water Res, 2014, 57: 151-61.
[7] Cole A C, Semmens M J, LaPara T M. Stratification of activity and bacterial community structure in biofilm grow on membranes transferring oxygen[J]. Applied and Environmental Microbiology , 2004, 70(4), 1982-1989.
[8] Lapointe B E, Herren L W, Debortoli D D, et al. Evidence of sewage-driven eutrophication and harmful algal blooms in Florida’s Indian River Lagoon[J]. Harmful. Algae, 2015, 43, 82-102.
[9] Chu H Q, Cao D W, Dong B Z, et al. Bio-diatomite dynamic membrane reactor for micro-polluted surface water treatment. Water Res, 2010, 44, 1573-1579.
 