Application of membrane gas absorption and ammonia desulphurization combination technique in the treatment of coal chemical waste gas |
Authors: LIU Zheng, GUAN Yipeng, CAO Zhen, LI Xuemei, CHEN Ying, WANG Wei, ZHANG Enwei, ZHOU Mingyuan, PENG Juan |
Units: The Institute of Seawater Desalination and Multipurpose Utilization, SOA(Tianjin), Tianjin 300192, China; 2. Hofung(Tianjin) Chemical Engineering Co., Ltd., Tianjin300384, China |
KeyWords: membrane gas absorption; Ammonia desulfurization; membrane absorption tower; coal chemical waste gas treatment; claus tail gas |
ClassificationCode:TQ028.8;X701.3 |
year,volume(issue):pagination: 2018,38(2):106-110 |
Abstract: |
In this study, we focus on the combination technique of membrane gas absorption (MGA) and ammonia desulfurization which were applied in the coal chemical waste gas treatment. A self-designed membrane absorption tower was employed in the experiment. Desulfurization efficiency, ammonia escape amount, the composition and purity of the absorption liquid were investigated in this process. 85~100m3/h feed gas was treated and the inflow SO2 concentration was 1500~3500mg/m3. The experiment results showed that the desulfurization efficiency was far below the national standard of SO2 emission and the ammonia escape amount was below 10mg/m3. Meanwhile, the ammonium sulfate solution has high grade purity which indicates the by-product a good potential economic value. The results of this study implied that the combination technique could be an upgrade or alternative of the traditional ammonia desulfurization process. |
Funds: |
海洋公益性科研专项项目(201305004) |
AuthorIntro: |
第一作者简介:刘铮(1982-),女,山东济南人,博士,工程师,研究方向为膜技术与应用;E-mail:liuzhengsh@foxmail.com 通讯作者,E-mail:chy786@163.com |
Reference: |
[1] D. deMontigny, P. Tontiwachwuthikul, A. Chakma. Comparing the absorption performance of packed columns and membrane contactors[J]. Industrial & Engineering Chemistry Research, 2005, 44(15):5726-5732 [2] 张慧峰,张卫东,张泽廷,等. 中空纤维膜吸收法脱除SO2的实验研究[J].环境科学与技术,2003,26(5):8-10 [3]金美芳,曹义鸣,邢丹敏,等. 膜吸收法脱除二氧化硫[J]. 膜科学与技术, 1999,19(3):44-47 [4]孙雪雁,杨凤林. 膜吸收法海水脱硫研究[J]. 膜科学与技术, 2008, 28(1):66-71 [5] R. Klaassen, A.E. Jansen. Achieving flue gas desulphurization with membrane gas absorption[J]. J. Filtration & Separation. 2003, 40(10): 26-28 [6] 陈颖,关毅鹏,张召才,等. 海水烟气脱硫膜吸收单元及工艺[J]. 膜科学与技术, 2011, 31(5): 58-63 [7] 李进,姚永毅,叶海,等. 中空纤维膜应用于烟气脱硫的现状与前景[J]. 四川环境,2007,26(1):72-76 [8] 陈颖,郭春刚,张召才,等. 一种新型低气阻箱式气液接触膜吸收单元[P]. 中国,实用新型专利:CN 202020991 U [9] 刘铮,关毅鹏,陈颖,等. 箱式膜吸收器用于烟气脱硫试验效果分析[J]. 化工设备与管道,2016,53(4):33-40 [10] 陈颖,王威,刘铮,等. 一种基于膜吸收氨法的化工废气脱硫处理工艺[P]. 中国,发明专利:CN 105854563 A,2016.08.17 [11] 徐启明,氨法脱硫装置存在的问题及解决方案[J].大氮肥,2013,36(2):102-104 [12] 关毅鹏,刘铮,陈颖,等. 多功能膜吸收塔[P]. 中国,发明专利:CN 106563335 A, 2017.04.19 [13] 范学友,贾勇,钟秦. 氨吸收法同时脱硫脱硝的实验研究[J].化工进展,2012,31(1):213-216 [14] 宋桂东,万皓,邵申,等. 氨法烟气脱硫中的氨逃逸[J].上海大学学报,2013,19(6):615-618 |
Service: |
【Download】【Collect】 |
《膜科学与技术》编辑部 Address: Bluestar building, 19 east beisanhuan road, chaoyang district, Beijing; 100029 Postal code; Telephone:010-80492417/010-80485372; Fax:010-80485372 ; Email:mkxyjs@163.com