Position:Home >> Abstract

Fouling behavior of ultrafiltration membrane caused by protein and humic acid mixtures
Authors: FENG Min, WANG Lei, YANG Zihan, MIAO Rui, LYU Yongtao
Units: Key Laboratory of Environmental Engineering of Shaanxi Province, Key Laboratory of Membrane Separation of Shaanxi Province, School of Environmental and Municipal Engineering Xi’an
KeyWords: ultrafiltration membrane; mixture foulants; fouling mechanism; microforces
ClassificationCode:TQ028.8
year,volume(issue):pagination: 2020,40(3):22-27

Abstract:
In this study, PVDF ultrafiltration membranes were used to filter the single pollutant solution of bovine serum albumin (BSA), humic acid (HA) and HA-BSA binary mixed pollutant solution, combined with the corresponding pollutant adsorption behavior on the membrane surface and the membrane. Contamination micro-force, analysis of ultrafiltration membrane pollution behavior of HA-BSA mixed pollutants. The results show that compared with BSA, the membrane fouling rate and irreversible pollution caused by the HA-BSA mixture are significantly slowed down; on the contrary, compared with HA, the HA-BSA mixture intensifies the membrane fouling rate and irreversible pollution. This is mainly caused by the difference in micro-effects of membrane pollution: HA-PVDF

Funds:
陕西省科技创新引导专项(2018HJCG-18) ;陕西省重点科技创新团队计划(2017KCT-19-01)

AuthorIntro:
第一作者简介:冯 敏(1995- ),女,陕西西安人,硕士研究生,主要从事超滤膜制备与污染机制研究,E-mail:757770624@qq.com *通讯作者,E-mail: wl0178@126.com

Reference:
[1]Qu F S, Liang H, Wang Z, et al. Ultrafiltration membrane fouling by extracellular organic matters (EOM) of Microcystis aeruginosa in stationary phase: influences of interfacial characteristics of foulants and fouling mechanisms [J]. Water research, 2012, 46(5): 1490-1500.
[2]黄 健, 舒增年, 张四海. 亲水荷电超滤膜的制备及对腐殖酸的分离性能 [J]. 中国环境科学, 2014, 34 (11): 2831-2837.
[3]Dhakal N, Salinas-Rodriguez S G, Ouda A, et al. Fouling of ultrafiltration membranes by organic matter generated by marine algal species [J]. Journal of Membrane Science, 2018, 555: 418-428.
[4]Goh P S, Lau W J, Othman M H D, et al. Membrane fouling in desalination and its mitigation strategies [J]. Desalination, 2018, 425: 130-155.
[5]Liu Y, Mi B. Combined fouling of forward osmosis membranes: Synergistic foulant interaction and direct observation of fouling layer formation [J]. Journal of Membrane Science, 2012, 407: 136-144.
[6]Peiris R H, Jaklewicz M, Budman H, et al. Assessing the role of feed water constituents in irreversible membrane fouling of pilot-scale ultrafiltration drinking water treatment systems [J]. Water Research, 2013, 47 (10): 3364-3374.
[7]Shi X, Field R, Hankins N. Review of fouling by mixed feeds in membrane filtration applied to water purification [J]. Desalination and Water Treatment, 2011, 35(1-3): 68-81.
[8]Jermann D, Pronk W, Meylan S, et al. Interplay of different NOM fouling mechanisms during ultrafiltration for drinking water production [J]. Water Research, 2007, 41(8): 1713-1722.
[9]Ye Y, Clech P L, Chen V, et al. Fouling mechanisms of alginate solutions as model extracellular polymeric substances [J]. Desalination, 2005, 175(1): 7-20.
[10]Gu Y, Wang Y, Wei J, et al. Organic fouling of thin-film composite polyamide and cellulose triacetate forward osmosis membranes by oppositely charged macromolecules [J]. Water Research, 2013, 47(5): 1867-1874.
[11]Mahlangu T O, Thwala J M, Mamba B B, et al. Factors governing combined fouling by organic and colloidal foulants in cross-flow nanofiltration [J]. Journal of Membrane Science, 2015, 491: 53-62.
[12]Zularisam A W, Ahmad A, Sakinah M, et al. Role of natural organic matter (NOM), colloidal particles, and solution chemistry on ultrafiltration performance [J]. Separation & Purification Technology, 2011, 78(2): 189-200.
[13]Guan Y, Qian C, Chen W, et al. Interaction between humic acid and protein in membrane fouling process: A spectroscopic insight [J]. Water Research, 2018, 145: 146-152.
[14]Wang L, Miao R, Wang X, et al. Fouling behavior of typical organic foulants in polyvinylidene fluoride ultrafiltration membranes: characterization from microforces [J]. Environmental Science & Technology, 2013, 47(8): 3708-3714.
[15]Yamamura H, Kimura K, Okajima T, et al. Affinity of functional groups for membrane surfaces: implications for physically irreversible fouling [J]. Environmental Science and Technology, 2008, 42(14): 5310-5315.
[16]Miao R, Wang L, Lv Y, et al. Identifying polyvinylidene fluoride ultrafiltration membrane fouling behavior of different effluent organic matter fractions using colloidal probes [J]. Water Research, 2014, 55: 313-322.

Service:
Download】【Collect

《膜科学与技术》编辑部 Address: Bluestar building, 19 east beisanhuan road, chaoyang district, Beijing; 100029 Postal code; Telephone:010-80492417/010-80485372; Fax:010-80485372 ; Email:mkxyjs@163.com