Position:Home >> Abstract

Optimization of Design and Operation Parameters for Pressurized Ultrafiltration Membrane Modules in Advanced Municipal Wastewater Treatment
Authors: Bai He, Lin Yakai, Li Ningning, Hu Yanping, Jin Yutao,Zhang Jinglong, Zheng Xiaohong, Ye Jingmei, Zhang Yangang
Units: (1.Beijing Scinor Membrane Technology Co. Ltd., Beijing, 100083, (2.China; Beijing Key Laboratory of Membrane Materials and Engineering, Department of Chemical Engineering, Tsinghua University, Beijing 100084, China; Beijing Scinor Water Technology Co. Ltd., Beijing, 100083, China
KeyWords: effective fiber length; operation flux; filtration period; backwash flux; municipal wastewater
ClassificationCode:X703
year,volume(issue):pagination: 2021,41(5):146-154

Abstract:
 Advanced treatment and reuse of municipal wastewater is an important part of the resource utilization. This paper introduces the application of polyvinylidene fluoride (PVDF) pressurized ultrafiltration membrane that produced via thermally induced phase separation (TIPS) in municipal wastewater project to study the effects of effective fiber length under different operation conditions on membrane performance, in order to provide a guidance for the subsequent development of other ultrafiltration applications in municipal wastewater advanced treatment. The results showed positive effect of shorter effective fiber length on TMP reducing and lower the fouling rate at the design of high packing density (0.8 m2/m3) and 1500 mm-1800 mm effective fiber length. The performance is more obvious under the conditions of the higher flux and filtration period. The results showed that the flux can be stabilized to 75 L/m2·h, the filtration period can be extended to 54 minutes for SMT900-P80, Both are better than SMT600-P80 with longer effective fiber length. The results also showed that reasonable parameters should be set according to the membrane module that used. The scanning electron microscopy (SEM) analysis and the turbidity of the permeate shows that the ultrafiltration membrane has good of pollutant removal effect and high anti-pollution performance, which will lead to the good application prospects.

Funds:
项目来源“清华大学春风基金”(2020Z99CFY041)

AuthorIntro:
白鹤(1991-),男,北京,硕士,工程师,水处理超滤膜应用,E-mail:Stefan19910130@hotmail.com

Reference:
 [1] 李圭白, 田家宇, 齐鲁. 第三代城市饮用水净化工艺及超滤的零污染通量[J]. 给水排水, 2010, 36(8): 11-15. 
[2] 操家顺, 陆晓光, 方芳. 浸没式超滤膜用于污水处理厂深度处理的试验[J]. 水资源保护, 2013, 29(3): 61-65.
[3] 孙德栋, 张启修. 用超滤法处理回用生活污水[J]. 中南工业大学学报: 自然科学版, 2003, 34(2): 144-147.
[4] 钱伶琤,雷晓玲,何栋奎. 超滤膜系统内部结构对膜过滤性能的影响[J]. 净水技术, 2012, 31(5): 42-45.
[5] Zhang, QH; Yang, WN; Ngo, HH; Guo, WS. Current status of urban wastewater treatment plants in China. Environ. Int. 2016, 92(93), 11–22.
[6] 左滢, 沈菊李, 吕晓龙, 朱圆圆. 超滤膜组件结构与性能研究[J]. 水处理技术, 2014, 40(9): 101-104. 
[7] 王捷, 张宏伟. 长度及出水方式对中空纤维膜过滤性能的影响[J]. 膜科学与技术, 2010, 30(3): 30-34.
[8] J. Gunther, P. Schmitz, C. Albasi, C. Lafforgue, A numerical approach to study the impact of packing density on fluid flow distribution in hollow fiber module[J]. Membr. Sci., 2010, 348 (1-2): 277.
[9] S.H. Yoon, H.S. Kim, I.T. Yeom, Optimization model of submerged hollow fiber membrane modules[J], Membr. Sci., 2004, 234(1-2): 147–156.
[10] 董声雄, 张济宇. 中空纤维膜低压超滤处理含油废水的数学模拟[J]. 化工学报, 2000, 51(3): 301-325.
[11] Tang Y, Lin Y, Wang X. PVDF membranes prepared via thermally induced (liquid–liquid) phase separation and their application in municipal sewage and industry wastewater for water recycling [J]. Desalination and Water Treatment, 2016, 57(47): 22258-22276.
[12] 朱圆圆, 沈菊李, 吕晓龙, 等. 浸没式超滤膜组件运行参数的优化[J]. 膜科学与技术, 2014, 34(6): 106-111.
[13] 徐振良. 膜法水处理技术[M]. 北京: 化学工业出版社,2001: 105-110. 
[14] Aoustin E, Schafer AI, Fane AG, et a1. Ultrafiltration of natural organic matter [J]. Separation and Purificmion Technology, 2001, 20(22-23): 63-78. 
[15] 范国庆, 王磊, 王旭东等. 水质环境条件对恒流超滤过程的影响研究[J]. 环境科学与技术, 2009, 32(10): 9-13.
[16]Aziz, M; Ojumu, T. Exclusion of Estrogenic and Androgenic Steroid Hormones from Municipal Membrane Bioreactor Wastewater Using UF/NF/RO Membranes for Water Reuse Application[J]. Membranes, 2020, 10(3), 37-39.
[17] 张博丰, 马世虎. 超/微滤膜的膜污染与膜清洗研究[J]. 供水技术, 2009, 3(6): 13-16. 
[18] He Bai, Yakai Lin. Technical and Economic Evaluation of WWTP Renovation Based on Applying Ultrafiltration Membrane[J]. Membranes, 2020, 10(8), 108-124.
[19] 蔡邦肖, 唐名威, 许阳. 自来水深度处理超滤膜的选择[J]. 工业用水与废水, 2007, 38(6): 71-75. 
[20] 曹秉直, 曹达文, 陈艳, 等. 饮用水膜深度处理技术[M]. 北京: 化学工业出版社, 2006: 87-110. 
[21] 何栋奎.给水超滤膜使用性能影响因素分析及其改善措施研究[D]. 重庆: 重庆交通大学市政工程系,2010. 
[22] 马琳, 秦国彤. 膜污染的机理和数学模型研究进展[J]. 水处理技术, 2007, 33(6): 1-4.

Service:
Download】【Collect

《膜科学与技术》编辑部 Address: Bluestar building, 19 east beisanhuan road, chaoyang district, Beijing; 100029 Postal code; Telephone:010-80492417/010-80485372; Fax:010-80485372 ; Email:mkxyjs@163.com

京公网安备11011302000819号