Position:Home >> Abstract

Study on the Influencing Factors of Oxygen Transfer Rate of the Membrane in Membrane Aerated Biofilm Reactor
Authors: Bao Jinfeng,Zhu Pinshang,Zhu Yuanyuan,Wu Kai,Xie Huifeng,Huang Xia
Units: 1 Zhejiang Kaichuang Env.Tech.Co, Ltd., Hangzhou, 310000, China; 2 Hangzhou Yuhang Water Holding Group Co. Ltd., Hangzhou, 310000; 3 Tsinghua Uniwersity, School of Environment, Beijing, 100084, China
KeyWords: membrane aerated biofilm reactor; oxygen transfer rate; concentration difference; influence factors
ClassificationCode:TQ028.8
year,volume(issue):pagination: 2023,43(2):123-127

Abstract:
 The oxygen transfer rate (OTR) of the membrane in membrane aerated biofilm reactor (MABR) has a great significance to the design of the MABR process. Factors affecting the OTR of the membrane in MABR were studied in this paper through a laboratory scale test. The results showed that under the same operating conditions the parallel connection mode of membrane modules had a faster OTR than the series connection mode. The average OTR of the membrane increased firstly and then gradually became stable with the increased air flow, increased slightly with the increased air pressure, had a little change with the elevated temperature, and decreased with the increased DO in water. The membrane in MABR had a certain oxygen transfer capacity after the air supply was stopped. Under the conditions of membrane modules connected in parallel, gas pressure of 2 kPa, and air flow of 100 mL·min-1, the average OTR reached as high as 12.7 g O2·m-2·d-1.

Funds:

AuthorIntro:
包进锋(1972-)浙江金华人,主要研究方向为污水处理技术,E-mail:baojf@zjkchb.com

Reference:
 [1] 宋新新,林甲,刘杰,等. 碳中和视野下面向未来污水处理关键技术研发与工程实践---“面向未来污水处理厂关键技术研发与工程示范”专栏序言[J].环境科学学报,2022,42(3).1-6.
[2]康晓峰,王黎声,刘春,等.膜曝气生物膜反应器生物脱氮研究进展[J].环境工程,2021,39(7).38-45.
[3]任乐辉,陈妹,王志伟.无泡曝气膜生物反应器污水处理研究及应用进展[J].水处理技术,2021,47(11).18-25.
[4]李玫,李保安,兰美超,等.新型MABR生物脱氮过程研究进展[J].膜科学与技术,2020,40(1).260-266. 
[5]Carles Pellicer-Nàcher, Carlos Domingo-Félez, Susanne Lackner, et al. Microbial activity catalyzes oxygen transfer in membrane-aerated nitritating biofilm reactors [J]. Journal of Membrane Science, 2013,446 ,465-471
[6] M.Castrillo, R. Díez-Montero, R. Díez-Montero, et al. Mass transfer enhancement and improved nitrification in MABR through specific membrane configuration[J]. Water Research,2019,152 ,1-11
[7]Rosso, D., Larson, L.E., Stenstrom, M.K., Aeration of large-scale municipal wastewater treatment plants: state of the art[J]. Water Sci. Technol. 2008.57 (7), 973–978.
[8]Aybar, M., Pizarro, G., Boltz, J.P., et al. Energy-efficient wastewater treatment via the air-based, hybrid membrane biofilm reactor(hybrid MfBR)[J]. Water Sci. Technol. 2014,69 (8), 1735-1741. 
[9] Mulder,M.著;李琳译.膜技术基本原理[M]. 2版.北京:清华大学出版社;1999,151~160
[10] 朱长乐著.膜科学技术[M]. 2版.北京:高等教育出版社;2004,340~347
[11]李保安,田海龙,李浩.膜曝气生物膜反应器微生物膜结构研究进展[J].膜科学与技术,2013,33(6).1-5.
[12]丁国良,程棋波,赵经纬,等.膜曝气生物膜反应器处理模拟生活污水研究[J].膜科学与技术,2020,40(5),95-100
[13] 中华人民共和国住房和城乡建设部,CJ/T 475-2015,微孔曝气器清水氧传质性能测定[S]. 北京:中国标准出版社, 2015.
 