Position:Home >> Abstract

Double-layer GO/PDA/CNT low-pressure membrane for humic acid removal and fouling control
Authors: WU Yaochen, ZENG Jia, WANG Yufei, WEI Na, LIU Qiushan, LIU Guohan, GUO Jin
Units: National Engineering Laboratory for Advanced Treatment and Reuse of Urban Sewage,Beijing University of Technology,Beijing 100124,China
KeyWords: carbon nanotubes; graphene oxide; low-pressure membrane; humic acid ;membrane fouling
ClassificationCode:
year,volume(issue):pagination: 2023,43(6):61-70

Abstract:
  Humic acid (HA) is a common membrane fouling substance and precursor of disinfection by-products in water. Carbon nanotubes (CNTs), polydopamine (PDA) and graphene oxide (GO) were used to prepare the double-layer GO/PDA/CNT low-pressure membrane by vacuum filtration. The presence of PDA on the surface of GO membrane was confirmed by ATR-FTIR analysis, and the stability of the double-layer membrane was verified by ultrasonic fragmentation. The permeability of the GO/PDA/CNT membrane was 1238 L/(m2·h·MPa), which was higher than that of the GO membrane with 279 L/(m2·h·MPa). The humic acid removal rate of GO/PDA/CNT membrane was 88.5%, higher than that of GO membrane (85.8%) and CNT membrane (38.9%). After filtration, the specific flux of GO membrane and CNT membrane decreased to 0.314 and 0.697, respectively. The specific flux of GO/PDA/CNT membrane decreased the least (0.753).Increasing the stirring rate improved the removal of HA and reduced membrane fouling. High stirring rate aggravated the membrane fouling. Under acidic condition the HA removal rate of GO/PDA/CNT membrane was the highest (94.5%) and the membrane fouling was the most serious. The preparation of GO/PDA/CNT double-layer membrane will improve membrane filtration efficiency and enhance the removal of humic substances, as well as reduce the generation of disinfection by-products.

Funds:
国家自然科学基金资助项目(51778014)

AuthorIntro:
吴曜辰(1997-),男,甘肃靖远人,硕士研究生,研究方向为污水深度处理与膜污染控制,E-mail:wu_yc@emails.bjut.edu.cn

Reference:
 [1] Kieffer R, Mangin D, Puel F, et al. Precipitation of barium sulphate in a hollow fiber membrane contactor, Part I: Investigation of particulate fouling[J]. Chem Eng Sci, 2009, 64(8):1759-1767.
[2] Chen X, Xu Y, Fan M, et al. The stimulatory effect of humic acid on the co-metabolic biodegradation of tetrabromobisphenol A in bioelectrochemical system[J]. J Environ Manage, 2019, 235:350.
[3] Fang J, Yang X, Ma J, et al. Characterization of algal organic matter and formation of DBPs from chlor(am)ination[J]. Water Res, 2010, 44(20):5897-5906.
[4] 董应超, 马丽宁, 朱丽, 等.碳纳米管复合膜的制备及水处理应用研究进展[J]. 膜科学与技术, 2016, 36(6):1-10.
[5] Ajmani G S, Goodwin D, Marsh K, et al. Modification of low-pressure membranes with carbon nanotube layers for fouling control[J]. Water Res, 2012, 46(17):5645-5654.
[6] Bai L, Liang H, Crittenden J, et al. Surface modification of UF membranes with functionalized MWCNTs to control membrane fouling by NOM fractions[J]. J Membr Sci, 2015, 492:400-411.
[7] Chu K H, Huang Y, Yu M, et al. Evaluation of graphene oxide-coated ultrafiltration membranes for humic acid removal at different pH and conductivity conditions[J]. Sep Purif Technol, 2017, 181:139-147.
[8] A Cerón-Vivas, J M Morgan-Sagastume, A Noyola. Intermittent filtration and gas bubbling for fouling reduction in anaerobic membrane bioreactors[J], J Membr Sci, 2012, 423–424:136-142.
[9] Kaya, Gokhan, et al. Analysis of wall shear stress on the outside-in type hollow fiber membrane modules by CFD simulation[J]. Desalination, 2014, 351:109-119.
[10] Bae T H, Tak T M. Interpretation of fouling characteristics of ultrafiltration membranes during the filtration of membrane bioreactor mixed liquor[J]. J Membr Sci, 2005, 264(1/2):151-160.
[11] Ye G, LEE J, Perreault F, et al. Controlled architecture of dual-functional block copolymer brushes on thin-film composite membranes for integrated “defending” and “attacking” strategies against biofouling[J]. ACS Appl Mater Interfaces, 2015, 7(41): 23069-79.
[12] Kwon Y, Leckie J. Hypochlorite degradation of crosslinked polyamide membranes: II. Changes in hydrogen bonding behavior and performance[J]. J Membr Sci, 2006, 282(1/2):456-464.
[13] Liu Z, Wu W, Liu Y, et al. A mussel inspired highly stable graphene oxide membrane for efficient oil-in-water emulsions separation [J]. Sep Purif Technol, 2018, 199:37-46.
[14] Meng H, Mi B. Enabling Graphene oxide nanosheets as water separation membranes[J]. Environ Sci Technol, 2013, 47(8):3715-3723.
[15] Chong J Y, Wang B, Mattevi C, Li K. Dynamic microstructure of graphene oxide membranes and the permeation flux[J]. J Membr Sci, 2018, 549:385-392.
[16] Zhong W, Zhang Y, Zhao L, et al. Highly stable and antifouling graphene oxide membranes prepared by bio-inspired modification for water purification[J]. Chin Chem Lett, 2020, 31(10):2651-2656.
[17] Han Y, Jiang Y Q, et al. High-flux graphene oxide nanofiltration membrane intercalated by carbon nanotubes[J]. ACS Appl Mater Interfaces, 2015, 7(15):8147-8155.
[18] Alkhouzaam A, Qiblawey H. Novel polysulfone ultrafiltration membranes incorporating polydopamine functionalized graphene oxide with enhanced flux and fouling resistance[J]. J Membr Sci, 2021, 620:118900.
[19] Zheng S, Tu Q, Urban J J, et al. Swelling of Graphene Oxide Membranes in Aqueous Solution: Characterization of Interlayer Spacing and Insight into Water Transport Mechanisms [J]. ACS Nano, 2017, 11(6):6440-50.
[20] 熊馨雅,曾嘉,董梦婵,盖晓莉,王宇飞,郭瑾.多巴胺非共价改性碳纳米管超滤膜的制备及抗污染性能[J].中国环境科学,2022,42(9):4207-4216.
[21] Amirhossein, Khalili-Garakani, et al. Analyze and control fouling in an airlift membrane bioreactor: CFD simulation and experimental studies[J]. Process Biochem, 2011, 46(5):1138-1145.
[22] Vyas H K, Bennett R J, Marshall A D. Cake resistance and force balance mechanism in the crossflow microfiltration of lactalbumin particles [J]. J Membr Sci, 2001, 192(1):165-76.
[23] Taheri A H, Sim L N, Haur C T, et al. The fouling potential of colloidal silica and humic acid and their mixtures[J]. J Membr Sci, 2013, 433:112-120.
[24] 王家宏, 毕丽娟, 马宏瑞, 等. 多壁碳纳米管对水中腐殖酸的吸附行为研究[J].陕西科技大学学报(自然科学版). 2012, 30(04):12-15+21.
[25] Dong M, Guo J, Wang Y, et al. Humic acid non-covalent functionalized multi-walled carbon nanotubes composite membrane and its application for the removal of organic dyes [J]. J Environ Chem Eng, 2022, 10(2):107320.
[26] 李伟娟. 土壤腐殖酸的质子解离平衡研究[J]. 辐射防护通讯, 1999(04):9-13.
[27] Lan T, Wu P, Liu Z, et al. Understanding the effect of pH on the solubility and aggregation extent of humic acid in solution by combining simulation and the experiment[J]. Environ Sci Technol, 2022, 56:917-927.