A2O-MBR组合工艺深度处理液晶TFT-LCD废水的试验研究 |
作者:王怀林,云金明,关晓琳,武克亮 |
单位: 江苏凯米膜科技股份有限公司,江苏 南京 210049 |
关键词: 膜生物反应器;TFT-LCD废水;深度处理 |
DOI号: |
分类号: X703 |
出版年,卷(期):页码: 2015,35(5):97-101 |
摘要: |
采用A2O-MBR组合工艺处理液晶TFT-LCD废水,并对其处理效果和工艺运行稳定性进行中试研究。试验结果表明,A2O-MBR组合工艺对液晶TFT-LCD废水具有良好且稳定的处理效果,在试验条件下,系统出水COD≤35mg/L、NH3-N≤5 mg/L、TN ≤15mg/L、TP≤0.33mg/L、浊度≤0.2NTU,可稳定达到《城市污水再生利用 城市杂用水水质》(GB/T18920-2002)的要求。试验运行期间,MBR系统可在高通量下稳定运行,跨膜压差始终在0.04bar~0.06bar之间,采用低浓度化学清洗对膜的渗透性能恢复较好。 |
Using the A2O-MBR combined process for treating TFT-LCD wastewater, and the treatment effect and operational stability were studied. The experimental results showed that the combined process of A2O-MBR has a good treatment effect and stability of TFT-LCD wastewater, under the experimental conditions, the effluent COD, NH3-N, TN, TP and turbidity were ≤35mg/L, ≤5mg/L, ≤15mg/L, ≤0.33mg/L, ≤0.2NTU, meeting the requirements of The reuse of urban recycling water--Water quality standard for urban miscellaneous water consumption (GB/T18920-2002). During the test, MBR system was stable operation at high flux, and the transmembrane pressure always between 0.04bar to 0.06bar, membrane permeability has a good recovery performance under the chemical cleaning of low concentration. |
基金项目: |
作者简介: |
参考文献: |
[1]刘建广等. 低氧下膜生物反应器强化脱氮除磷[J]. 膜科学与技术,2007, 27(4):70~73. [2]邹联沛,张立秋,王宝贞等. MBR中DO对同步硝化反硝化的影响[J].中国给水排水,2001, 17 (6):10~14. [3]张志超,黄霞,肖康等. 脱氮除磷膜-生物反应器的除磷效果及特性[J].清华大学学报:自然科学报,2008, 48 (9):92~94. |
服务与反馈: |
【文章下载】【加入收藏】 |
《膜科学与技术》编辑部 地址:北京市朝阳区北三环东路19号蓝星大厦 邮政编码:100029 电话:010-64426130/64433466 传真:010-80485372邮箱:mkxyjs@163.com